  page 1/3 9january2014/version 21 lem reserves the right to carry out modifcations on its transducers, in order to improve them, without prior notice www.lem.com i pn = 200 .. 1500 a v out = 4 v features hall effect measuring principle insulating plastic case recognized according to ul 94-v0. advantages easy installation low power consumption small size and space saving only one design for wide current ratings range high immunity to external interference. applications dc motor drives switched mode power supplies (smps) ac variable speed drives uninterruptible power supplies (ups) battery supplied applications power supplies for welding applications. application domain industrial. current transducer hat 200 .. 1500-s for the electronic measurement of currents: dc, ac, pulsed,..., with galvanic separation between the primary circuit and the secondary circuit. electrical data type primary nominal primary current, rohs since rms current measuring range 1) date code i pn (a) i pm (a) hat 200-s 200 600 47143 hat 400-s 400 1200 46115 hat 500-s 500 1500 46129 hat 600-s 600 1800 46115 hat 800-s 800 2400 46115 hat 1000-s 1000 2500 46097 hat 1200-s 1200 2500 77271 hat 1500-s 1500 2500 46158 u c supply voltage ( 5 %) 1) 15 v i c current consumption 15 ma r is insulation resistance @ 500 v dc > 1000 m? v out output voltage (analog) @ i pn , r l = 10 k?, t a = 25 c 4 v r out output internal resistance 100 ? r l load resistance > 10 k? accuracy - dynamic performance data x accuracy @ i pn , t a = 25 c (excluding offset) 1 % of i pn l linearity error 2) (0 .. i pn ) 1 % of i pn v oe electrical offset voltage @ t a = 25 c < 20 mv v oh hysteresis offset voltage @ i p = 0, after an excursion of 1 x i pn < 10 mv tcv oe temperature coeffcient of v oe - 40 c .. + 80 c < 1 mv/k + 80 c .. + 105 c < 1.5 mv/k tcv out temperature coeffcient of v out (% of reading) < 0.1 %/k t r step response time to 90 % of i pn < 5 s di/dt di/dt accurately followed > 50 a/s bw frequency bandwidth 3) (- 3 db) dc .. 25 khz general data t a ambient operating temperature - 40 .. + 105 c t s ambient storage temperature - 40 .. + 105 c m mass 300 g standards en 50178: 1997 ul 508: 2010 4) notes: 1) operating at 12 v u c < 15 v will reduce the measuring range 2) linearity data exclude the electrical offset 3) please refer to derating curves in the technical fle to avoid excessive core heating at high frequency 4) ul conform is only applicable @ t a = - 40 c .. + 85 c. u c u c r m i p d ci d cp n 64.02.44.000.0, n 64.02.48.000.0, n 64.02.50.000.0, n 64.02.52.000.0 n 64.02.56.000.0, n 64.02.60.000.0, n 64.02.62.000.0, n 64.02.65.000.0 specime n
page 2/3 9january2014/version 21 lem reserves the right to carry out modifcations on its transducers, in order to improve them, without prior notice www.lem.com current transducer hat 200 .. 1500-s insulation coordination u d rms voltage for ac insulation test, 50 hz, 1 min 4.9 kv ? w impulse withstand voltage 1.2/50 s > 9.9 kv min d cp creepage distance 11 mm d ci clearance 11 mm cti comparative tracking index (group iiia) 275 applications examples according to en 50178 and iec 61010-1 standards and following conditions: over voltage category iii pollution degree pd2 non-uniform feld safety this transducer must be used in limited-energy secondary circuits according to iec 61010-1. this transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturers operating instructions. caution, risk of electrical shock when operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). ignoring this warning can lead to injury and/or cause serious damage. this transducer is a build-in device, whose conducting parts must be inaccessible after installation. a protective housing or additional shield could be used. main supply must be able to be disconnected. en 50178 iec 61010-1 d cp , d ci , ? w rated insulation voltage nominal voltage basic insulation 1100 v 1100 v reinforced insulation 550 v 550 v specime n
page 3/3 9january2014/version 21 lem reserves the right to carry out modifcations on its transducers, in order to improve them, without prior notice www.lem.com u c u c r m i p d ci d cp dimensions hat 200 .. 1500-s (in mm) mechanical characteristics general tolerance 1 mm transducer fastening by base-plate or on busbar with m4 screws all holes ? 4.5 mm recommended fastening torque 1.2 nm ( 10 %) connection of secondary molex 5045-04a remarks v out is positive when i p fows in the direction of the arrow. temperature of the primary conductor should not exceed 105 c. installation of the transducer must be done unless otherwise specifed on the datasheet, according to lem transducer generic mounting rules. please refer to lem document nane120504 available on our web site: products/product documentation . u c u c r m i p d ci d cp ?? ? ?? ? u c u c r m i p d ci d cp u c u c r m i p d ci d cp connection specime n


▲Up To Search▲   

 
Price & Availability of HAT1000-S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X